11kv-Silicone-rubber-lightning-Arrester

Short Description:

Place of Origin: China

Brand Name: Powertek

Model Number: HY5WZ

Material: Silicone rubber & Zinc oxide

Color: grey and customizable

Rated Voltage: 33KV

Application: Over-Voltage Protection

Type: outdoor

NEMA bracket: Include

Standard: IEC60099-4

OEM production: Accept

Mounting plate: Include


  • b01
  • b05
  • b06
  • 8ab12aa5
  • 3

Product Detail

Product Tags

Supply Ability

1000000 Piece/Pieces per Year

Packaging & Delivery

Packaging Details: Standard export packing or According to customer's requirement

Port: Tianjin

Main Principle

The metal-oxide arrester is the most advanced over-voltage protector in the word. They protects the electrical equipment in AC power systems against being damaged by atmospheric over-voltage and operational over-voltage.

This is due to the incorporation of a zinc oxide arrester as the core resistor disc. This allows an improvement in the volt-ampere characteristics of the resistor disc and an increase in through-current capability in over-voltage situations, which is a drastic improvement when compared to conventional silicon carbide arresters. Under normal operating voltage, the current through the arrester is only one micro-ampere degree. When the arrester experiences an over-voltage situation, the excellent non linear characteristics will increase the current through the arrester several thousand times. The arrester is in the conducting state and will release the over-voltage energy to earth and thereby protecting power transmission equipment against the effects of over-voltage.

Normal operating conditions for lightning surge arrester

1. The ambient air temperature is not higher than +40 Celsius and not lower than -40 Celsius;

2. The altitude above sea level do not exceed 1000-2000m. (Altiplano area should be indicated when order);

3. The frequency in AC system in 50Hz or 60Hz;

4. Power frequency voltage which has been bearing on arrester for a long time do not exceed continuous operating voltage;

5. Max. wind speed do not exceed 35m/s;

6. Apply to the area where earthquake intensity is not exceed 8 degree;

7. The filthy area should be indicated before.

8. Power frequency voltage brought to bear on arrester for a long time does not exceed the continuous operation voltage of the arrester.

9. Maximum wind speed does not exceed 35m/s.

10. Te earthquake intensity does not exceed 7 degrees.

11. The pollution area should be indicated.

Specification

5KA Polymeric Housed Metal-oxide Surge Arrester without Gaps Electrical Parameter

Type MOA Rated voltage (KVrms) MCOV KV(rms) Current impulse Residual Voltage 2ms Rectangular current impulse withstand A(crest) 4/10μs high current impulse withstand KA(crest)
1/4μs Lightning current impulse KV(crest) 8/20μs Lightning current impulse KV(crest) 30/60μs Switching current impulse KV(crest)
YH5W-3 3 2.55 11.3 9 8.9 150 65
YH5W-6 6 5.1 22.6 18 16.8 150 65
YH5W-9 9 7.65 33.7 27 23.8 150 65
YH5W-10 10 8.4 36 30 23 150 65
YH5W-11 11 9.4 40 33 30 150 65
YH5W-12 12 10.2 42.2 36 27 150 65
YH5W-15 15 12.7 51 45 38.5 150 65
YH5W-18 18 15.3 61.5 54 46.2 150 65
YH5W-21 21 17 71.8 63 54.2 150 65
YH5W-24 24 19.5 82 72 62 150 65
YH5W-27 27 22 92 81 69.8 150 65
YH5W-30 30 24.4 102 90 79 150 65
YH5W-33 33 27.5 112 99 86.7 150 65
YH5W-36 36 29 123 108 92.4 150 65

Note: if it is porcelain,without”H”

10KA Polymeric Housed Metal-oxide Surge Arrester without Gaps Electrical Parameter

Type MOA Rated voltage (KVrms) MCOV KV(rms) Current impulse Residual Voltage 2ms Rectangular current impulse withstand A(crest) 4/10μs high current impulse withstand KA(crest)
1/4μs Lightning current impulse KV(crest) 8/20μs Lightning current impulse KV(crest) 30/60μs Switching current impulse KV(crest)
YH10W-3 3 2.55 11.3 9 8.9 250 100
YH10W-6 6 5.1 22.6 18 16.8 250 100
YH10W-9 9 7.65 33.7 27 23.8 250 100
YH10W-10 10 8.4 36 30 23 250 100
YH10W-11 11 9.4 40 33 30 250 100

Our Advantage

1.The low weight facilitates installation and permits erection in limited spaces and at almost all angles.

2.No continuous current and low current impulse residual voltage.

3.Excellent pollution and short circuit performance.

4.Safe to touch when energised by accident.

5.Stable U-I characteristics,even after multiple strikes.

6.Resistant to UV,ozone,chemicals,mechanical abuse.

7.Fully qualified following IEC60099-4, IEEE.C62.11, GB11032-2000.

8.Over 15 years’ manufacturing experience on lightning surge arrester.